Search results for "Outflow tract"

showing 10 items of 19 documents

Diagnostic electrophysiological study in a highly trained young woman with presyncopal symptoms during exercise: a case report

2021

Right ventricular outflow tract (RVOT) ventricular tachycardia (VT) is frequent and occurs in patients without structural heart disease, especially in highly trained athletes. Most of the studies on cardiac adaptations to exercise have been investigated in male athletes. Women, however, are increasingly participating in sports and electrical and structural adaptations in male and female athletes differ significantly. These cardiac adaptations dissimilarities between males and females have potential implications in diagnosing certain types of arrhythmias. We present here a case of a 35-year-old highly-trained woman endurance athlete that attended the clinic complaining about chest pain and d…

0301 basic medicineTachycardiamedicine.medical_specialtyPresyncopeHeart diseasebusiness.industryCase ReportGeneral Medicine030204 cardiovascular system & hematologyChest painmedicine.diseaseVentricular tachycardia03 medical and health sciencesQRS complex030104 developmental biology0302 clinical medicineInternal medicineHeart ratemedicineCardiologyVentricular outflow tractmedicine.symptombusiness
researchProduct

Mitral and aortic regurgitation in 84 patients with mucopolysaccharidoses

1995

In echocardiographic and necropsy studies nodular thickening of the mitral valve and, less frequently, of the aortic valve has been found in 60%-90% of patients with mucopolysaccharidoses (MPS). Little is known about the haemodynamic consequences of these morphological changes. In this study 84 unselected patients with different enzymatically proven MPS and 84 age and sex matched, healthy persons were studied prospectively by colour Doppler flow mapping. The patients' age ranged from 1 to 47 years (median 8.1 years). Mitral and aortic regurgitation were defined as a holosystolic or holodiastolic jet originating from the valve into the left atrium or the left ventricular outflow tract, respe…

AdultMaleAortic valvemedicine.medical_specialtyAdolescentAortic Valve InsufficiencyHemodynamicsRegurgitation (circulation)Doppler echocardiographyMitral valveInternal medicinemedicineHumansVentricular outflow tractProspective Studiescardiovascular diseasesChildskin and connective tissue diseasesMitral regurgitationmedicine.diagnostic_testbusiness.industryInfantMitral Valve InsufficiencyMiddle AgedMucopolysaccharidosesEchocardiography Doppler ColorSurgerymedicine.anatomical_structureChild PreschoolPediatrics Perinatology and Child Healthcardiovascular systemCardiologyFemaleComplicationbusinessEuropean Journal of Pediatrics
researchProduct

Heart valve tissue engineering: how far is the bedside from the bench?

2015

Heart disease, including valve pathologies, is the leading cause of death worldwide. Despite the progress made thanks to improving transplantation techniques, a perfect valve substitute has not yet been developed: once a diseased valve is replaced with current technologies, the newly implanted valve still needs to be changed some time in the future. This situation is particularly dramatic in the case of children and young adults, because of the necessity of valve growth during the patient's life. Our review focuses on the current status of heart valve (HV) therapy and the challenges that must be solved in the development of new approaches based on tissue engineering. Scientists and physicia…

Aortic valveHeart diseaseSwine030204 cardiovascular system & hematology0302 clinical medicineHeart valve tissue engineeringHyaluronic AcidChildProsthetic valve0303 health sciencesMARROW-DERIVED CELLSTissue ScaffoldsFetal BloodHeart Valves3. Good healthmedicine.anatomical_structureHeart Valve ProsthesisCardiologyMolecular MedicineCollagenmedicine.medical_specialtyPULMONARY VALVEBONE-MARROWInduced Pluripotent Stem CellsVENTRICULAR OUTFLOW TRACTMESENCHYMAL STEM-CELLS03 medical and health sciencesTissue scaffoldsInternal medicineEXTRACELLULAR-MATRIXmedicineAnimalsHumansHeart valveIntensive care medicineENDOTHELIAL PROGENITOR CELLSMolecular Biology030304 developmental biologyBioprosthesisAORTIC-VALVEFibrinSheepTissue Engineeringbusiness.industryEndothelial Cellsmedicine.diseaseTransplantationPulmonary valveUMBILICAL-CORD BLOOD1182 Biochemistry cell and molecular biologybusinessHUMAN AMNIOTIC-FLUIDExpert Reviews in Molecular Medicine
researchProduct

A rule‐based method to model myocardial fiber orientation in cardiac biventricular geometries with outflow tracts

2019

Rule-based methods are often used for assigning fiber orientation to cardiac anatomical models. However, existing methods have been developed using data mostly from the left ventricle. As a consequence, fiber information obtained from rule-based methods often does not match histological data in other areas of the heart such as the right ventricle, having a negative impact in cardiac simulations beyond the left ventricle. In this work, we present a rule-based method where fiber orientation is separately modeled in each ventricle following observations from histology. This allows to create detailed fiber orientation in specific regions such as the endocardium of the right ventricle, the inter…

FOS: Computer and information sciencesmedicine.medical_specialtyHeart VentriclesBiomedical EngineeringFOS: Physical sciencesVolume mesh030204 cardiovascular system & hematology[INFO.INFO-AI]Computer Science [cs]/Artificial Intelligence [cs.AI]030218 nuclear medicine & medical imagingComputational Engineering Finance and Science (cs.CE)03 medical and health sciences0302 clinical medicineRule-based methodInternal medicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingmedicineHumansComputer SimulationElectrophysiological simulationsInterventricular septumOutflow tractComputer Science - Computational Engineering Finance and ScienceMolecular BiologyEndocardiumFiber (mathematics)Orientation (computer vision)MyocardiumApplied MathematicsFiber orientationOutflow tract ventricular arrhythmiaModels CardiovascularRule-based systemSeptumMagnetic Resonance Imaging[INFO.INFO-MO]Computer Science [cs]/Modeling and SimulationPhysics - Medical PhysicsElectrophysiological Phenomenamedicine.anatomical_structureComputational Theory and MathematicsVentricleModeling and Simulationcardiovascular systemCardiologyOutflowMedical Physics (physics.med-ph)SoftwareGeologyInternational Journal for Numerical Methods in Biomedical Engineering
researchProduct

Transcatheter radiofrequency perforation and stent implantation for palliation of pulmonary atresia in a 3060-g infant

1995

In a 3060-g infant with fibromuscular pulmonary atresia an open right ventricular outflow tract was created by means of interventional cardiological methods. Following two inadvertent perforations without sequelae or clinical symptoms, radiofrequency perforation and subsequent balloon dilatation were successfully performed. The implantation of a Palmaz iliac stent led to a predictable communication between the right ventricle and pulmonary artery.

Heart Septal Defects VentricularCardiac Catheterizationmedicine.medical_specialtymedicine.medical_treatmentPerforation (oil well)Coronary Angiographymedicine.arterymedicineHumansVentricular outflow tractmedicine.diagnostic_testbusiness.industryInfant NewbornStentmedicine.diseaseSurgerymedicine.anatomical_structureEchocardiographyPulmonary AtresiaVentricleAtresiaAngiographyPulmonary arteryCatheter AblationFemaleStentsRadiologyCardiology and Cardiovascular MedicinePulmonary atresiabusinessCatheterization and Cardiovascular Diagnosis
researchProduct

Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement

2013

Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…

Malemedicine.medical_specialtyCardiac CatheterizationTranscatheter aorticAortic rootmedicine.medical_treatmentAortic Rupturemultidetector computed tomographySettore MED/11 - Malattie dell'Apparato CardiovascolareCohort StudiesValve replacementPredictive Value of TestsRisk FactorsPhysiology (medical)Internal medicineMultidetector computed tomographymedicine80 and overVentricular outflow tractHumanscardiovascular diseasesannular calcification; annular rupture; multidetector computed tomography; transcatheter heart valves; Aged; Aged 80 and over; Angioplasty Balloon; Aortic Rupture; Aortic Valve; Aortic Valve Stenosis; Calcinosis; Cohort Studies; Female; Heart Valve Prosthesis Implantation; Humans; Logistic Models; Male; Predictive Value of Tests; Risk Factors; Tomography X-Ray Computed; Cardiac CatheterizationTomographyAgedAged 80 and overHeart Valve Prosthesis Implantationbusiness.industrySinotubular JunctionAngioplastyCalcinosisAortic Valve Stenosismedicine.diseaseX-Ray ComputedBalloon expandable stentLogistic Modelstranscatheter heart valvesAortic ValveCardiologycardiovascular systemannular ruptureFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAngioplasty BalloonBalloonCalcificationannular calcification
researchProduct

Gerbode-type left ventricular outflow tract to right atrial fistula complicating prosthetic aortic valve replacement identified by cardiac computed t…

2012

Abstract Acquired left ventricular-right atrial communication ( Gerbode-type defect) is a rare complication of infective endocarditis. Although transesophageal echocardiography remains the technique of choice for the evaluation of complications of endocarditis this case highlights the usefulness of cardiac computed tomography in this scenario, particularly in cases where assessment of coronary anatomy is required before surgery.

Malemedicine.medical_specialtyFistulaHeart DiseasesHeart VentriclesFistulaCoronary AngiographyRight atrialDiagnosis DifferentialPostoperative ComplicationsAortic valve replacementInternal medicinemedicineHumansEndocarditisVentricular outflow tractRadiology Nuclear Medicine and imagingHeart Atriabusiness.industryMiddle Agedmedicine.diseaseComputed tomographic angiographyAortic ValveHeart Valve ProsthesisInfective endocarditiscardiovascular systemCardiologyRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicineComplicationbusinessJournal of Cardiovascular Computed Tomography
researchProduct

Direct measurement of left ventricular outflow tract by transthoracic real-time 3D-echocardiography increases accuracy in assessment of aortic valve …

2007

Evaluation of aortic valve stenosis is a major clinical application of echocardiography. The widely employed continuity equation requires determination of the left ventricular outflow tract (LVOT) area. We aimed at testing whether direct area measurement in a volume data set is superior to conventional calculation from the LVOT diameter.We performed LVOT measurement in 20 normal subjects and 83 patients with moderate to severe aortic stenosis with a transthoracic real-time three-dimensional echocardiography (3D-TTE) technique in two systolic frames. The off-line 3D-evaluation allows full choice of section planes within the acquired volume data set. The aortic valve area was calculated from …

Moderate to severeAortic valveAdultMalemedicine.medical_specialtyEchocardiography Three-DimensionalReal time 3d echocardiographyVentricular Outflow ObstructionYoung AdultInternal medicinemedicineVentricular outflow tractHumansSystoleAgedAged 80 and overbusiness.industryAortic Valve StenosisMiddle Agedmedicine.diseaseStenosismedicine.anatomical_structureAortic valve areaEchocardiographyAortic valve stenosisCardiologyFemaleCardiology and Cardiovascular MedicinebusinessInternational journal of cardiology
researchProduct

Impact of Aortic Diameter Measurements at Three Anatomical Landmarks on Left Ventricular Output Calculation in Neonates

2021

OBJECTIVES To assess reproducibility and accuracy of left ventricular output (LVO) quantifications in neonates, when left ventricular outflow tract diameter (LVOTD) was measured at the hinges of the aortic valve (AV), at the aortic sinus (AS), and at the sinotubular junction (STJ). METHODS This was an observational study. In the first cohort of very preterm neonates, we assessed intraobserver and interobserver repeatability of LVOTD measured at the AV, AS, and STJ and of the corresponding LVO. In the second cohort of older neonates, we compared paired LVO measurements by echo and magnetic resonance imaging (MRI). RESULTS In the first cohort of 48 neonates, mean (standard deviation) weight a…

Observer VariationAortic valveReproducibilityRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryHeart VentriclesLimits of agreementInfant NewbornReproducibility of ResultsMagnetic resonance imagingRepeatabilitymedicine.anatomical_structureEchocardiographyAortic ValveAortic sinusHumansMedicineVentricular outflow tractRadiology Nuclear Medicine and imagingAortic diameterbusinessNuclear medicineJournal of Ultrasound in Medicine
researchProduct

New Technique for Aortic Valve Functional Annulus Reshaping Using a Handmade Prosthetic Ring

2011

Background Despite a wide development in aortic leaflets repair techniques, aortic valve annuloplastic procedures are still poorly investigated. We present our aortic valve annuloplastic system consisting of a handmade prosthetic ring with 2 components for reshaping the aortic annulus and sinotubular junction (STJ) and illustrates our surgical approach and clinical results. Methods Since February 2003, 45 patients with aortic valve regurgitation underwent aortic annuloplasty using the new ring. Mean patient age was 58 ± 16 years (range, 46 to 76 years). The ring has 2 components: a circular ring used to undersize the circumference of the aortoventricular junction and 3-crown-like shape ring…

Pulmonary and Respiratory MedicineAortic valveMalemedicine.medical_specialtymedicine.medical_treatmentAortic Valve InsufficiencyRegurgitation (circulation)Ring (chemistry)Prosthesis DesignInternal medicinemedicineVentricular outflow tractHumansCardiac skeletonAortic valve regurgitationAgedHeart Valve Prosthesis Implantationbusiness.industryAortic valve annulus reshapingSinotubular JunctionStentSettore MED/23 - Chirurgia CardiacaMiddle Agedmedicine.diseaseSurgerymedicine.anatomical_structureAortic ValveHeart Valve Prosthesiscardiovascular systemCardiologySurgeryFemaleCardiology and Cardiovascular Medicinebusiness
researchProduct